Operating Instructions
Chapter
8
CLX490
8009237/RB47/2007-08-03
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8-13
Troubleshooting
8.5.4
Malfunctions in Reading mode: errors in the result status output
¾
Check whether the "Device Ready" LED lights up.
If the LED does not light, see
.
Malfunction
Possible cause
Remedy
The
– "Result 1"
(default setting: Device Ready)
– "Result 2"
(default setting: Good Read)
– "Result 3"
(default setting: No Read)
– "Result 4"
(default setting: Match 1)
switching outputs are not outputting any
pulses
•
The event associated with the assigned
function for outputting the result status of
the read does not occur in the reading
operation.
•
Incorrect switching mode parameterized
in the CLX.
•
Not applicable.
•
In the "CLV-Setup" program: choose the
D
EVICE
C
ONFIGURATION
tab. Click the R
E
-
SULT
O
UTPUT
P
ARAMETERS
button. Are the
outputs set to N
O
I
NVERT
O
UTPUT
? Change
if necessary. Download to CLX!
Table 8-8: Troubleshooting: errors in the result status output in Reading mode