Operating Instructions
CLX490 Compact OMNI Scanner
5-14
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Electrical installation
5.5.4
Connecting the host interface
Risk of damage to the interface module!
Electrical components in the CLX may be damaged if the host interface is connected
incorrectly. This also applies when the host interface connections are changed in the
Connection Modules (configuration).
¾
Connect the host interface as shown in
¾
Check the connections carefully before you switch on the CLX.
¾
Connect the host interface on the CLX to the host using shielded cables (EMC require-
ments). Ensure that the maximum cable lengths are not exceeded (see
).
Default
In the default setting, the CLX communicates with the host via the host interface using the
values shown in
.
Fig. 5-2:
Connecting the host interface
AMV60-011/AMS60-012, -013
RS 232
RS 422
CAN-Network:
Connection diagram for SICK CAN Scanner Network see "CLV Connect" program on CD-ROM
Terminal assignment
( )=9-pin Sub D
plug on PC
Parameter Value
Physical design
RS 422/485
Data transfer rate
9.600 bd
Data bits
8
Parity None
Stop bits
1
Protocol
SICK (start character: STX, stop character: ETX, no request for repeat:
none, timeout: 50 ms)
Table 5-16: Communication parameters for the host interface (default setting)