Operating Instructions
Chapter
5
CLX490
8009237/RB47/2007-08-03
©
SICK AG · Division Auto Ident · Germany · All rights reserved
5-13
Electrical installation
5.5
Electrical installation procedur
5.5.1
Individual steps
•
Connect the power supply
•
Connect the host interface
•
Connect the PC (connect the auxiliary interface)
•
Connect the "Sensor" and "IN 0 to IN 4" switching inputs
•
Connect the "Result 1 to Result 4" switching outputs
5.5.2
Tools
•
Tool
•
Digital measuring device (current/voltage measurement)
5.5.3
Connecting the supply voltage
a) SICK AMV/S and BMV10 Connection Modules
If the CLX is powered via the SICK Connection Modules, the supply voltage does not have
to be wired separately.
Connecting the CLX without external parameter memory:
1.
Make sure that the power supply to the Connection Module is switched off.
2.
Connect the "Host/Term" and "I/O" connections on the CLX to the corresponding
connections on the Connection Module using two cables no. 2020302 and secure
them tightly on both sides.
Connecting the CLX with external parameter memory:
1.
Mount the connector cover with the external parameter memory no. 2020307 on the
"Host/Term" and "I/O" connections of the CLX and screw it tightly into position.
2.
Connect the two free plug connections on the cables to the corresponding connections
on the Connection Module and secure them tightly.
The data and function interfaces of the CLX are connected to the Connection Module.
b) Power supply via non-SICK Power pack
Connecting the CLX without external parameter memory:
1.
Connect the cable socket on cable no. 2020303 on the "Host/Term" connection and
screw it tightly into position.
2.
Connect the cable plug on the cable no. 2020264 to the "I/O" connection and screw
it tightly into position.
3.
Connect the power supply to the red wire (Pin 1, V
S
) and blue wire (Pin 5, GND) on cable
no. 2020303.
Connecting the CLX with external parameter memory:
1.
Connect the "Host/Term" and "I/O" connections on the CLX to the corresponding con-
nections on the Connection Module using two cables no. 2020981 and secure them
tightly on both sides.
2.
Connect the power supply to the red/pink wire (Pin 1, VS) and the blue/grey-brown wire
(Pin 5, GND) of cable 1. See also
The CLX is connected to the supply voltage.