Operating Instructions
Chapter
6
CLX490
8009237/RB47/2007-08-03
©
SICK AG · Division Auto Ident · Germany · All rights reserved
6-11
Operation
b) Parameterizing the reading trigger source:
Parameterizising the laser timeout:
c) Parameterizising the evaluation characteristics
•
Choose decoder type
Ö
C
ODE
C
ONFIGURATION
tab
Ö
Decoder
•
Activate code types for evaluation
Ö
C
ODE
C
ONFIGURATION
tab
Ö
Codes and Edit Codes
•
Activate code comparison
Ö
D
EVICE
C
ONFIGURATION
tab
Ö
Match Codes Parameters
•
Define output time of reading result
Ö
C
ODE
C
ONFIGURATION
tab
Ö
Output on Good Read
Action
Settings
1. Reading trigger: choose source for start
Ö
D
EVICE
C
ONFIGURATION
tab
Ö
Section R
EADING
T
RIGGER
S
OURCE
– Sensor Input (Active High) or
– Sensor Input (Active Low) or
– Serial Interface or
– Free-running with Timeout or
– OPC-Trigger (special application) or
– OTS-Trigger (special application)
2. Trigger source "Sensor Input": Choose de-
bouncing and response with firsttrigger
Ö
R
EADING
T
RIGGER
P
ARAMETERS
Ö
D
EBOUNCING
S
ENSOR
– Standard or
– Fast
Ö
F
IRST
T
RIGGER
S
ENSOR
– Dynamic or
– Static
3. Trigger source "Serial Interface":
choose trigger character
Ö
R
EADING
T
RIGGER
P
ARAMETERS
Ö
S
ERIAL
I
NTERFACE
– Standard Trigger or
– Single Character
4. Trigger source "Free-running":
choose timeout
Ö
R
EADING
T
RIGGER
P
ARAMETERS
Ö
E
ND
OF
L
ABEL
/F
REE
-
RUNNING
– Timeout
5. Reading trigger: choose source for end
Ö
R
EADING
T
RIGGER
P
ARAMETERS
Ö
E
ND
OF
R
EADING
I
NTERVAL
– Generated by Trigger Source or
– Timer or
– Generated by "IN 4" switching input
Table 6-6: Guide: Parameterizing the reading trigger source
Action
Settings
1. Choose laser timeout duration
– or –
Ö
D
EVICE
C
ONFIGURATION
tab
Ö
R
EADING
T
RIGGER
P
ARAMETERS
Ö
L
ASER
T
IMEOUT
– Duration
2. Deactivate laser timeout
(The laser diode is always active, when trig-
gered, independent of the pulse duration)
Ö
L
ASER
TIMEOUT
– Click (deactivate) the control box I
NTERVAL
ACTIVE