COMMISSIONING
6
91
8020776/12AX / 2019-05-31|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S |Free Flow Profiler
Align the LMS Width so that the setting is also suitable for the LMS Axle.
•
Rotation about the
X-axis
(first field): The signal must be output at an angle of 90° in
relation to the
road surface
.
•
Rotation about the
Y-axis
(second field): The signal must be output at an angle of 90°
in relation to the
direction of travel
.
•
Rotation about the
Z-axis
(third field): The device’s rear panel must be perpendicular to
the road surface.
A rotational error of ± 2° is tolerated for all axes.
Calibrating the LMS Width
▸
Calibrate the
LMS Width
using the calibration wizard (see
Applying the calibration positions from LMS Width
1. Take the calibration positions from the
LMS Width
system component and apply them
to the
LMS Axle
system component.
2. The symbols for both system components are now congruent again in the live view.
Rotation