COMMISSIONING
6
87
8020776/12AX / 2019-05-31|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S |Free Flow Profiler
Visualization of the calibration range
Once you have selected it, the reference object appears in the live view.
The value table at the top of the
Calibration wizard
area shows the position of the
reference object within the coordinate system. The
Box Filter Settings
table allows you to
set the range for recording measurement points as part of the calibration process.
The graphical display shows the sides of the reference object that can be “seen” by the
2D LiDAR sensor and the current positions of the measurement points. Use the display to
help you set the calibration range exactly.
▸
Place the mouse pointer on the graphical display and zoom in on a section of the image
where the reference lines of the object and the measurement points can be clearly
identified.
The reference object must be positioned within the measuring range so that the 2D LiDAR
sensor will definitely be able to detect two sides. The reference lines and measurement
points should always be L-shaped.
Important