Parameter Description
Parameter Description
•
The mode of operation is presented in the figure below:
Note: 1. The parameter P.100, P.101~P.108, P.111~P.118 and P.121~123 is only for programmed operation mode. In
the manually operation circle mode, the acceleration time is determined by
P.7
, and the deceleration time is
determined by
P.8
.
2. The inverter will run across most of the eight section, and the frequency is determined by P.131~P.138
3. When the frequency is set, the inverter will run standby in this section if any section is 0. It means that at
the third mode the value of P.131 is not 0. Like the figure above, no matter what are the values of P.137
and P.138, the inverter will stop when pressing the sixth switch.
4. The manually operation circle mode has a single rotation direction. It has nothing to do with P.121 and STF
or STR signal.
5.39 Operation Panel Frequency Monitoring Selection Function (P.110)
P.110 “Operation panel frequency monitoring selection”
Parameter Factory
Setting
Setting
Range
Remarks
0
When the inverter starts, the operation panel enters the
monitoring mode automatically, and the screen displays
the output frequency.
1
When the inverter starts, the screen of the operation panel
displays the target frequency.
2
When the inverter starts, the operation panel enters the
monitoring mode automatically, and the screen displays
the output frequency steady.
3
When the inverter starts, the operation panel enters the
monitoring mode automatically, and the screen displays
the current pressure and feedback pressure of the constant
pressure system (note).
110
0
0~4
4
When the inverter starts, the operation panel keeps the
previous mode.
frequency
M0
ON
ON
ON
ON
ON
ON
ON
ON
……
P.131
P.132
P.133
P.134
P.135
P.131
P.132
0