5.20 Multi-function Output (P.40, P.64, P.74, P.85, P.120 and P.187)
P.40 “Multi-function output terminal
pattern”
P.64 “Pulse output selection”
P.74 “10X output selection”
P.85 “Function selection for
multi-function relay”
P.120 “The output signal delay time”
P.187 “FM calibration parameter”
Related parameters
P.41 “Up-to-frequency sensitivity”
P.42 “Output frequency detection
for forward rotation”
P.43 “Output frequency detection
for reverse rotation”
P.62 “Zero current detection”
P.63 “Zero current detection time”
Parameter Factory Setting Setting Range
Remarks
-
-
-
0
1
~
0
0
0
4
64
0
0, 1
74
0
0~10
P.64=0, P.74=0 SO function
P.64=1, P.74=0 FM function
P.64=1, P.74=1~10 10X function
-
-
-
0
1
~
0
5
5
8
-
-
-
s
0
0
6
3
~
0
s
0
0
2
1
187
220
0~9998
The calibrating values, therefore the default value
for each machine may differ slightly.
< Setting >
•
When set different value to P40/P.85, the function of the SO-SE (SO function)/A-B-C terminal is
below:
n
o
it
c
n
u
f
r
e
t
e
m
a
r
a
P
0
RUN (Inverter running): Signal will be output when the output frequency is equal
to or higher than the starting frequency.
1
SU (Up to frequency): Signal will be output once the output frequency has reached
the set region of frequency.
2
FU (Output frequency detection): Signal will be output once the output frequency
has reached or exceeded the detection frequency set.
3
OL (Overload detection): Signal will be output once the current limit function is
triggered.
4
OMD (Zero current detection): If the output current percentage of the inverter is
less than the set value of
P.62
, and lasts for the pre-defined time (the setting value
of
P.63
), OMD will output signal.
5 ALARM (Alarm detection): Alarm detection
P.40/P.85
6
PO1 (Section detection): At the programmed operation mode, PO1 signal will be
output in the end of each section.