Parameter Description
Parameter Description
s
k
r
a
m
e
R
e
g
n
a
r
g
n
it
t
e
S
g
n
it
t
e
s
y
r
o
t
c
a
F
r
e
t
e
m
a
r
a
P
288
0
0~12
289
0
---
The value of P.288, 1~12, corresponds to the
abnormal codes of P.289’s alarm E1~E12.
290
0
0~5
291
0
---
When P.290=1, P.291 corresponds to the frequency
when the alarm goes off.
When P.290=2, P.291 corresponds to the current
when the alarm goes off.
When P.290=3, P.291 corresponds to the output
voltage when the alarm goes off.
When P.290=4, P.291 corresponds to the
accumulation rate of temperature increase when the
alarm goes off.
When P.290=5, P.291 100 corresponds to the
(+/P)-(-N) voltage when the alarm goes off.
If both P.288 and P.290 are 0, P.289 and P.291 will be displayed as 0.
Abnormal code corresponded alarm condition:
Abnormal
Number
Alarm
Code
Abnormal
Number
Alarm
Code
Abnormal
Number
Alarm
Code
Abnormal
Number
Alarm
Code
00 (H00) No alarm 33 (H21)
OV2
64 (H40)
EEP
160 (HA0)
OPT
16 (H10)
OC1
34 (H22)
OV3
66 (H42)
PIDE
179 (HB3)
SCP
17 (H11)
OC2
35 (H23)
OV0
97 (H61)
OLS
192 (HC0)
CPU
18 (H12)
OC3
48 (H30)
THT
98 (H62)
OL2
193 (HC1)
CPR
19 (H13)
OC0
49 (H31)
THN
129 (H81)
AErr
32 (H20)
OV1
50 (H32)
NTC
144 (H90)
OHT
5.61 Accumulative motor operation time function (P.292, P.293)
P.292 “Accumulative motor operation time (minute)”
P.293 “Accumulative motor operation time (day)”
Parameter
Factory Setting
Setting Range
Remarks
-
-
-
n
i
m
9
3
4
1
~
0
0
2
9
2
-
-
-
y
a
d
8
9
9
9
~
0
0
3
9
2
<Setting>
•
P.292 means the minutes of accumulative motor operation, execute
P.998
, shut off the power, and
the updated value cannot change the value of P.292. The only way to clear the accumulation of time
is to set P.292 to 0.