Parameter Description
Parameter Description
5.26 Remote Control Function (P.61)
P.61 “Remote setting function selection”
If the operation box is located away from the control box, contact signals can be used to perform
the continuous variable-speed operation without using analog signals at the external mode, the PU
mode, the combined mode 1 or the combined mode 5.
Remarks
Parameter Factory
Setting
Setting
Range
Set
Value
Remote Set
Function
Frequency Setting Storage Function
-
-
-
o
N
0
s
e
Y
1
o
N
2
61
0
0~3
3
Yes
No
(The remote setting frequency is cleared
by turning off STF/STR.)
<Setting>
• R
emote setting function
1. Whether the remote setting function is valid and whether the frequency setting storage function in
the remote setting mode is used is selected by P.61.
Set P.61=1~3 (remote setting function is valid), the function of terminals RM, RH and RL are
changed to acceleration (RH), deceleration (RM) and clear (RL). As shown in the following
Figure:
Wiring of remote control setting
Acceleration (RH)
Deceleration (RM)
Clear (RL)
Forward rotation(STF)
ON
ON
ON
ON
ON
ON
ON
ON
ON
P. 61
=
1
P. 61
=
3
P. 61
=
2
、
3
P. 61
=
1
、
2
Power supply
Output
frequency
(Hz)
0
Time
*
*external target frequency (except multi-speed) or PU target frequency
Inverter
Forward rotation
Acceleration
Deceleration
Clear
STF
RH
RL
RM
SD
10
5
2