6
3
Primary Operation
Primary Operation
4.2 Basic Operation Procedures for Different Modes
4.2.1 Basic operation procedures for the PU mode (P.79=0 or 1 )
n
o
it
p
ir
c
s
e
D
s
p
e
t
S
1
•
Change the operation mode to PU mode, and the indicating lamp of
will be lit up.
Note: 1. When
P.79
=0, after the power is switched on or the inverter is reset, the inverter will
enter the external mode first.
2. For selecting and switching the operation modes, please refer to
Section 4.1
.
2
•
Enter into the frequency setting mode, and write the target frequency into the memory.
Note: Please refer to
Section 4.1.4
for the detailed setting procedures.
3
•
Press
or
REV
.
r
o
t
o
m
e
h
t
n
u
r
o
t
•
At this time, the indicating lamp of
will flicker, indicating that the motor is
running. The operation panel then enters into the monitoring mode automatically. (Please
refer to P.110 in Chapter 5 for detailed descriptions.)
Note: 1. Please refer to
Section 4.1.3
for the operating flow of the monitoring mode.
2. The frequency setting mode is valid while the motor is running, and thus the target frequency can
be changed to regulate the motor speed.
4
•
Press
STOP
RESET
and the motor will start to decelerate until it stops.
•
The indicating lamp of
will stay on until the inverter stops outputting voltages.
4.2.2 Basic operation procedures for external mode (
, P.79=0 or 2)
n
o
it
p
ir
c
s
e
D
s
p
e
t
S
1
•
The indicating lamp of
will be lit up when changing the operation mode to the
external mode.
Note: 1. When
P.79
=0, press
to switch to the operating mode after the power is turned on or the inverter
is reset. The inverter will enter the external mode first, then press
or
to shift to PU
mode.
2. When P.79=2, the inverter will always be at the external mode.
3. Please refer to
Section 4.1
for selecting and switching the operation modes.
2
•
Please refer to
P.39
in Chapter 5 if the target frequency is set by the input signal across
terminal 4-5.
•
Please refer to
P.4
in Chapter 5 if the target frequency is set by multi-speed stage levels.
•
Please refer to
P.38
in Chapter 5 if the target frequency is set by the input signal across
terminal 2-5.
•
Please refer to multi-function terminals
P.80~P.84, P.86
in Chapter 5 if programmable
operating mode is chosen.
MODE
FWD