95
Parameter Description
Parameter Description
Para-
meter
Termi
nal
Factory
Setting
Setting
Range
Value
Name Function Instruction
28 RUN
At the external mode, the
inverter runs when RUN is on.
29 STF/STR
At the external mode, it is
used with RUN. The inverter
runs forwards when STF/STR
is on, and runs reversely when
STF/STR is off.
Run forward
/reverse
control signal
30 RES
External
Reset
31 STOP
At the external mode, it can
be used as a three-wire mode
with the RUN signal or the
STF/STR terminal (note 4).
32 REX
Multi-speed
33 PO
At the external mode,
programmed operation mode
is chosen when PO is on.
84 STR 1
0~40
,43
34 RES_E
When the alarms occur,
external Reset became
effective
35 MPO
At the external mode,
manually operation circle
mode is chosen when MPO is
on.
36 TRI
Triangle wave function is
chosen when TRI is on.
37 GP_BP
Automatic switchover
frequency between inverter
and commercial power-supply
operation
38 CS
Manual switch for
commercial power-supply.
39
STF/STR
+STOP
At the external mode, it is
used with RUN. The inverter
runs reverse when STF/STR is
on and stops when STF/STR
is off. If you need runs
forwards, you should RUN
again.
40 P_MRS
When P_MRS is turned on,
the output stop immediately.
P_MRS is a
pulse signal
41
P_FRE
Frequency set by pulse
Only for
terminal M2
86 RES 30
0~40
,43
43 RUN_EN
When RUN_EN is turned on,
terminals for external
operation signal became
effective