8
3
Primary Operation
Primary Operation
4.2.5 Basic operation procedured for combined mode 1 ( , P.79=4 )
n
o
it
p
ir
c
s
e
D
s
p
e
t
S
1
•
At the combined mode 1, the indicating lamp of
will flicker.
Note: Please refer to
Section 4.1
for selecting and switching the operation modes,
2
•
Enter into the frequency setting mode and write the target frequency into the memory.
Note: For operation procedures of the frequency setting mode, please refer to
Section 4.1.4
.
3
•
Set up the target frequency by the
operation panel
and start the inverter by the
external
terminals
.
•
The indicating lamp of
will flicker, indicating that the motor is running.
Note: For operating procedures of the monitoring mode, please refer to
Section 4.1.3
.
4
•
Turn off STF or STR for the motor to decelerate till it stops.
•
The indicating lamp of
will stay on until the inverter has stopped putting out
voltages.
4.2.6 Basic operation procedures for the combined mode 2 (
, P.79=5)
n
o
it
p
ir
c
s
e
D
s
p
e
t
S
1
•
At the combined mode 2, the indicating lamp of
will flicker.
Note: For selecting and switching the operation mode, please refer to
Section 4.1
.
2
•
The
target frequency
is set by
external terminals
.
•
If the target frequency is set by the input signal across terminal 4-5, please refer to
P.39
in
Chapter 5.
•
If the target frequency is set by multi-speed stage levels, please refer to
P.4
in Chapter 5.
•
If the target frequency is set by the input signal across terminal 2-5, please refer to
P.38
in
Chapter 5.
•
If the target frequency is set by pulse, please refer to
P.82
in Chapter 5.
3
•
Press
FWD
or
REV
to run the motor. The indicating lamp of
will flicker, indicating
that the motor is running.
Note: 1. For operating procedures of the monitoring mode, please refer to
Section 4.1.3
.
2. The frequency setting mode is valid in case the motor is running, and thus the target frequency can
be changed to regulate the motor speed.
4
•
Press
STOP
RESET
to decelerate the motor till it stops.
•
Indicating lamp of
will stay on until the inverter has stopped putting out voltages.