Parameter Description
Parameter Description
Parameter Factory Setting Setting Range
Remarks
0
No detection of over torque
155
0%
0~200%
0.1~200%
When detecting the over torque,
alarm is displayed and the motor
stopped.
-
-
-
s
0
6
~
0
s
1
6
5
1
100%
P.155
output
P.156
OL
Reset signal
Output current (%)
Invertor display the OL2 alarm,and the output
stopped,the motor stopped too.
(Overload alarm)
full load current level
time
5.42 External Terminal Filter Function (P.157)
P.157 “External terminals filter function selection”
Parameter
Factory Setting
Setting Range
s
m
0
0
2
~
0
4
7
5
1
•
P.157 selects response time to the signal of external terminal.
5.43 External Terminal Power Enable Function (P.158)
P.158 “External terminal power enable”
Parameter
Factory Setting
Setting Range
1
~
0
0
8
5
1
•
If P.158=1, select the external terminal power enabling function. At this situation, if the
multi-function terminal function is STF, STR, RUN or MPO and the opposite terminal is connected
before the power is on, then the inverter will not run. The user should connect it to the terminal
again and the inverter will start running. If P.158=1, the terminal is connected before the power is
on, and if the power is on, the inverter will run immediately.