Primary Operation
Primary Operation
Related
Parameters Values
Operation
Mode
Reference Source of Target
Frequency
Signal Source of Motor
Starting
Remarks
4
Combined
mode 1
operation panel
External terminals
5
Combined
mode 2
External voltage/current
signal
,
combination of
multi-speed stage levels
or frequency set by pulse
(P.82)
Press the key
FWD
or
REV
on
the operation panel.
6
Combined
mode 3
Communication
,
combination of
multi-speed stage levels
or
External JOG (P.15)
External terminals
7
Combined
mode 4
External voltage/current
signal
,
combination of
multi-speed stage levels
or frequency set by pulse
(P.82)
Communication
(Note )
Operation
Mode
Selection
P.79
8
Combined
mode 5
Operation panel
,
combination of
multi-speed stage levels
or
external JOG(P.15)
External terminals
Note: If
P.79
=0, the inverter is in the external mode (
when starting, and the operating mode
can be shifted by setting P.79.