71
Parameter Description
Parameter Description
Modbus
Code
Item
Shihlin
Protocol
Code
Information Content and Functions
Modbus
Address
H03 Inverter
State H7A
H0000~H00FF
b8~b15
˖
reserved
b7
˖
Alarm occurrence
b6
˖
Frequency detection
b5
˖
Parameters to default values end.
b4
˖
Overload
b3
˖
Frequency achieved
b2
˖
Reverse rotation
b1
˖
Forward rotation
b0
˖
Operation
H1001
Set frequency
H73
H0000~H9C40
H1002
Output
frequency
H6F H0000~H9C40
H1003
Output current
H70
H0000~HFFFF
H1004
Output voltage
H71
H0000~HFFFF
H1005
H74 H1007
H03
Monitoring
Alarm
item
H75
H0000~HFFFF:
H74/H1007
˖
Error code 1 and 2
b15 b8 b7 b0
Error code 2
Error code 1
H75/H1008
˖
Error code 3 and 4
b15 b8 b7 b0
Error code 4
Error code 3
Error code can reference the
table
in alarm
history parameters.
H1008
H06/H10 Operation
command HFA
H0000~HFFFF
b8~b15: reserved
b7: scram
˄
MRS
˅
b6: 2
nd
Acceleration/Declaration
Selection(RT)
b5: High Speed (RH)
b4: Mid Speed (RM)
b3: :Low Speed (RL)
b2: REV Rotation(STR)
b1: FWD Rotation (STF)
b0: reserved
H1001
H06/H10 Inverter
reset HFD
H9696
˖
The function of
P.997
Communicate with the computer: the
inverter can not send data back to the
computer because it has been reset.
H1101