5
2
1
Parameter Description
Parameter Description
5.67 Inverter Reset (P.997)
P.997 “Inverter reset”
Once P.997 is read-out (after the read-out, the screen will display
) and rewritten-in, the
inverter is reset. After resetting the inverter, the values of the two relays, “electronic thermal relay”
and “IGBT module thermal relay”, will be set to zero.
5.68 Restoration of the Parameters to the Default Values (P.998 and P.999)
P.998 “Restoring the parameters to the default values”
P.999 “Restoring some parameters to the default values”
Once P.998 is read-out (after the read-out, the screen will display
) and rewritten-in, all the
parameters will be restored to the default values except
P.21
,
P.188
,
P.189
,
P.292
and
P.293
.
Once P.999 is read-out (after the read-out, the screen will display
) and rewritten-in, all the
parameters will be restored to the default values except P.21, P.188, P.189,
P.190~P.191
,
P.192~P.195
,
P.196~P.199
, P.292, P.293 and
P.300
~
P.309
.
After performing P.998 and P.999, the screen will display
, indicating that the parameters
have been restored to the default values