22
Introduction of Shihlin Inverter
Introduction of Inverter
Control terminals
Terminal Type
Terminal
Name
Function
Name
Remarks and Function Description
STF Optional
STR Optional
M0 Optional
M1 Optional
M2 Optional
RES Optional
These terminals are multi-function control terminals
SINK/SOURCE mode switchable
.
For detailed descriptions, please refer to
P.80~P.84, P.86
in
Chapter 5.
SD SD
Common reference ground for STF, STR, M0, M1, M2 and
RES
On-off Signal
Input
PC PC
,
n the ‘Source input’ mode, it provides a common DC24V
power supply which Allow load current 50 mA for the
terminals referred to above.
10 ---
The internal power is DC 10V at this terminal which Allow
load current 5 mA
2 ---
The input point of voltage signal 0~5V or
0~10V, is used to set the target frequency.
P.38
4 ---
The input point of voltage signal 0~5V or
0~10V/input points of current signal
4mA~20mA
switch with
P.17
, is used to set
the target frequency.
Note 1
P.39
Analog Signal
Input
5
---
The common reference ground of 2, 4, 10 and AM.
A ---
B ---
Relay Output
C ---
Normally, points A-C are always open-circuit, and points B-C
are always short-circuit.
Contact capacity is
VDC30V /
VAC230V-0.3A
SO Optional
The terminal can also be called a multi-function output
terminal;
contact capacity is
VDC24V-0.1A. The function name
can be set by
P.40
. For detailed description, please refer to
P.40 in Chapter 5.
Open Collector
Output
SE
SE
Open collector output reference ground.
Analog Signal
Output
AM ---
Connected with an external analog meter to indicate the
output frequency or current.
Contact capacity is
0~10VDC/2mA.
Please refer to
P.54, P.55, P.56, P.191, and P.192
in Chapter 5.
Communication
Terminal
RJ45
---
Communication terminal for DU06 or PC.