7-156
SYSTEM SETTINGS
►
SYSTEM SETTINGS
Automatic
This function controls the power optimally for each time period by analyzing the use of machine based on job logs
obtained during a certain time period.
Manual
You can set a pattern for each time band.
The machine already has the 3-pattern template. The Energy Save pattern can be added to the "Original Eco Patterns 1
to 4".
Three-pattern template
Sleep Mode Power Level
Low Power:
The machine switches to the power saving mode, but it takes some time to recover.
Fast Wake Up:
Compared with Low Power, the power value rises by a certain degree, but it results in faster recovery.
Motion Sensor:
This enables switching of power saving modes by the motion sensor.
Mode2 (Job Start
Priority2)
After 30 minutes
150 to 699
Mode3 (Energy Saving
Priority1)
After 5 minutes
40 to 149
Mode4 (Energy Saving
Priority2)
After the minimum time period
Up to 39
Sleep Mode Power
Level
Low Power :The machine switches to the power saving mode, but it
takes some time to recover.
Fast Wake Up :Compared with Low Power, the power value rises
by a certain degree, but it results in faster recovery.
Motion Sensor:This enables switching of power saving modes by
the motion sensor.
–
If the machine does not have the 4-week job log information, the machine enters the template2 (Mode3 (Energy Saving
Priority1) between 8:00 and 18:00 hours). Then after that, it enters Mode4 (Energy Saving Priority2).
Template
Pattern
Description of mode
Template 1
All Day "Energy Save
Priority2"
The machine runs in the "Mode4 (Energy Saving Priority2)" all the
time.
Template 2
8:00-18:00 "Energy Save
Priority1"
The machine runs in "Mode3 (Energy Saving Priority1)" between 8:00
and 18:00, and in "Mode4 (Energy Saving Priority2)" at other times.
Template 3
8:00-18:00 "Job Start
Priority1"
The machine runs in "Mode1 (Job Start Priority1)" between 8:00 and
18:00, and in "Mode4 (Energy Saving Priority2)" at other times.
Pattern
Transition time
Average outputs per
hour