7
2.3 Technical specifications
Power specifications
Typ
S A N I C U B I C
®
GR
Power
P1
[kW]
Power
P2
[kW]
Voltage
U
[V]
Power
reception
I
N
[A]
Rotational
speed
[n
-1
]
Flage
Pump
Inlet
Inlet
height
h [mm]
SE71.1 S
2,2
1,7
230
10,5
2 800
DN 50 single unit:
DN 100
DN 50/100
double unit:
DN 100
DN 100/150
250
576
250
586
SE71.1 T
2,1
1,7
400
3,7
2 800
DN 50
SE71.2 T
2,1
1,7
400
3,7
2 800
DN 50
SE71.3 T
3,9
3,2
400
6,5
2 800
DN 50
SE71.4 T
3,9
3,2
400
6,5
2 800
DN 50
Maximum medium temperature: 55°C
Materials
Container
PE HD
Cutting blade
Stainless steel
Pump housing
GG 20
Motor shaft
Stainless steel
Rotor
GG 20
Seals
NBR, FPM
Seal supports
GG 20
Axial face seals
SiC (silicon carbide)
Cutting flange
Stainless steel
2.4 Area of usage
The effluent lifting units of the SANICUBIC
®
GR production series are used for the disposal (collection
and conveying) of domestic and industrial effluent that develops underneath the canal backflow level.
The model with cutting unit pumps enables pumping off over greater conveying heights and pressure
main lengths. The pressure main may be laid at a dimension of DN 50.
Double systems are used wherever an interruption of the effluent disposal system is not permitted to
occur, in terms of DIN 1986.
2.5 Scope of delivery
The effluent lifting units of the SANICUBIC
®
GR production series are delivered with:
• assembled cutting unit pump(s) of the SANIPUMP
®
ZFS 71 production series
• connection for emergency evacuation
• pneumatic control and switch boxes
• inflow bend DN 100
• flexible connection for ventilation of the collection chamber
• pressure decrease bend DN 50
• back-kick flap(s) DN 50
• forked pipe DN 50/50/50 (only for double system)
3. TRANSPORT AND INTERIM STORAGE
3.1 Transport
The effluent lifting units of the SANICUBIC
®
GR production series may not be thrown or dropped.
Moreover, they are to be transported in a horizontal position.
3.2 Interim storage/conservation
The machine can be kept in interim storage and conserved in a cool, dark, dry and frost-free site. The
systems should stand in horizontal position.
Summary of Contents for SANICUBIC 1 GR
Page 2: ...English 3 Deutsch 17 Français 32 Italiano 48 Nederlands 64 Español 80 Português 96 ...
Page 12: ...12 Appendix A Main dimensions SANICUBIC 1 GR ...
Page 13: ...13 SANICUBIC 2 GR ...
Page 15: ...15 Appendix D Section diagram and spare parts list of the pump Section diagram ...
Page 27: ...27 Anhang A Hauptabmessungen SANICUBIC 1 GR ...
Page 28: ...28 SANICUBIC 2 GR ...
Page 30: ...30 Anhang D Schnittzeichnung und Ersatzteilliste der Pumpe Schnittzeichnung ...
Page 43: ...43 Annexe A Dimensions principales SANICUBIC 1 GR ...
Page 44: ...44 SANICUBIC 2 GR ...
Page 59: ...59 Allegato A Dimensioni principali SANICUBIC 1 GR ...
Page 60: ...60 SANICUBIC 2 GR ...
Page 62: ...62 Allegato D Disegno in sezione e lista ricambi della pompa Disegno in sezione ...
Page 75: ...75 Bijlage A Hoofdafmetingen SANICUBIC 1 GR ...
Page 76: ...76 SANICUBIC 2 GR ...
Page 78: ...78 Bijlage D Doorsnedetekening en lijst met reserveonderdelen van de pomp Doorsnedetekening ...
Page 91: ...91 Anexo A Dimensiones principales SANICUBIC 1 GR ...
Page 92: ...92 SANICUBIC 2 GR ...
Page 94: ...94 Anexo D Dibujo seccional y listado de piezas de recambio de la bomba Dibujo seccional ...
Page 107: ...107 Anexo A Dimensões principais SANICUBIC 1 GR ...
Page 108: ...108 SANICUBIC 2 GR ...
Page 110: ...110 Anexo D Desenho seccional e lista de peças sobressalentes da bomba Desenho seccional ...