Startup of MOVIMOT
®
with MLK30A in Easy mode
Startup procedure
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
50
6.5.3
Data AS-Interface master → MOVIMOT
®
The following table shows the 4 data bits that the AS-Interface master sends to the
MOVIMOT
®
inverter via the AS-Interface:
AS-Interface
bit
Function (
DO0
CW operation/stop
DO1
CCW operation/stop
DO2
Speed f2/speed f1
DO3
Reset
1)
/controller enable
1) In the event of an edge change from "0" → "1" (only effective in case of an error)
INFORMATION
To enable the drive, AS-Interface bit DO3 "reset/controller enable" must be set.