6
Startup of MOVIMOT
®
with MLK30A in Easy mode
Description of the DIP switches S1
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
42
Drive ID module
Motor
Identification
ID color
Part number
Line voltage [V]
Mains frequency
[Hz]
DRU...J/400/50
Gray
28203194
230/400
50
Setting DIP switch S1/6:
Power
Motor type
MOVIMOT
®
MM..D-503-00 inverter
Motor in
W
connection
Motor in
m
connection
[kW]
S1/6 = OFF
S1/6 = ON
S1/6 = OFF
S1/6 = ON
0.25
DR
U
71SJ/..
–
–
MM
03
D..
–
0.37
DR
E
71SJ4/..
DR
U
71MJ4/..
MM
03
D..
–
MM
05
D..
–
0.55
DR
E
71MJ4/..
DR
U
80SJ4/..
MM
05
D..
–
MM
07
D..
–
0.75
DR
E
71MJ4/..
DR
U
80MJ4/..
MM
07
D..
–
MM
11
D..
–
1.1
DR
E
80SJ4/..
DR
U
90MJ4/..
MM
11
D..
–
MM
15
D..
–
1.5
DR
E
80MJ4/..
DR
U
90LJ4/..
MM
15
D..
–
MM
22
D..
–
2.2
DR
E
90MJ4/..
DR
U
100MJ4/..
MM
22
D..
–
MM
30
D..
–
3.0
DR
E
90LJ4/..
DR
U
100LJ4/..
MM
30
D..
–
MM
40
D..
–
4.0
DR
E
100MJ4/..
MM
40
D..
–
–
–
6.3.4
DIP switch S1/7
Setting the maximum PWM frequency
• When DIP switch S1/7 is set to "OFF", the MOVIMOT
®
works with the PWM fre-
quency of 4 kHz.
• When DIP switch S1/7 is set to "ON", the MOVIMOT
®
works with the PWM fre-
quency of 16 kHz (low-noise). MOVIMOT
®
incrementally switches back to lower
clock frequencies depending on the heat sink temperature and the load on the in-
verter.
6.3.5
DIP switch S1/8
No-load vibration damping
When setting DIP switch S1/8 to "ON", this function reduces resonance vibrations
when in no-load operation.
21328994/EN – 11/2014