7
Service
Error list
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
60
Code
Error
Possible cause
Measure
07
DC link voltage too
high
Ramp time too short.
Extend the ramp time.
Reset error
1)
.
Faulty connection between
brake coil/braking resistor
Check the braking resistor/brake coil connec-
tion. Correct, if necessary.
Reset error
1)
.
Incorrect internal resist-
ance of brake coil/braking
resistor
Check internal resistance of brake coil/braking
resistor (see operating instructions, chapter
"Technical data").
Reset error
1)
.
Thermal overload of the
braking resistor, size of
braking resistor incorrectly
selected
Dimension the braking resistor correctly.
Reset error
1)
.
Invalid voltage range of
supply input voltage
Check supply input voltage for permitted volt-
age range.
Reset error
1)
.
08
Speed monitoring
Speed deviation due to op-
eration at the current limit
Reduce the load on the drive.
Reset error
1)
.
09
Startup
Non-permitted drive ID
module with MOVIMOT
®
with 230 V supply
Not all drive ID modules are permitted for
MOVIMOT
®
with 230 V supply (see operating
instructions, chapter "Drive ID module assign-
ment").
Check/remedy drive ID module.
For MOVIMOT
®
MM..D
with AS-interface, the addi-
tional function 4, 5, 12 are
not permitted.
Correct the settings of DIP switches S2/5 –
S2/8.
11
Thermal overload of
the output stage or
internal unit error
Heat sink is dirty.
Clean the heat sink.
Reset error
1)
.
Ambient temperature too
high.
Lower ambient temperature.
Reset error
1)
.
Heat build-up on
MOVIMOT
®
drive.
Prevent heat build-up.
Reset error
1)
.
Drive load too high.
Reduce the load on the drive.
Reset error
1)
.
15
24 V monitoring
24 V supply voltage dip
Check 24 V supply.
Reset error
1)
.
17 - 24
37
CPU errors
CPU errors
Reset error
1)
.
21328994/EN – 11/2014