5
Electrical installation
Connection of MOVIMOT® MM../AND3/AZSK (connection option C)
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
28
5.5
Connection of MOVIMOT
®
MM../AND3/AZSK (connection option C)
Connection
of
MOVIMOT®
MM../AND3/
AZSK
(connection
option C)
The following figure shows the connection in MM../AND3/AZSK design:
0V
L3
N.C.
N.C.
N.C.
L1
3
1
2
4
24V
24V
0V
3
1
2
4
[1]
3
1
2
4
3
1
2
4
[3]
AS-Int
AS-Interface -
[4]
V024
V0
PE
DI2
DI3
[2]
1
2
2
1
3
3
4
4
X02
X03
X01
YE
BK
BK
X02
X03
X01
PE
N.C.
L2
N.C.
27021598888335371
AZSK plug connector
[1]
X01:
M12 plug connector
(male, black)
1 24 V
24 V supply (AUX-PWR)
2 N.C.
Not assigned
3 0 V
Reference potential AUX-PWR
4 N.C.
Not assigned
[2]
X03:
M12 plug connector
(female, black)
1 V024
24 V voltage supply for sensors
2 DI3
Sensor input DI3
3 V0
⍊
0 V reference potential for sensors
4 DI2
Sensor input DI2
5 PE
PE
[3]
X02:
M12 plug connector
(male, yellow)
1 AS-Int
AS-Interface data cable +
2 0 V
Reference potential AUX-PWR
3 AS-Interface -
AS-Interface data cable -
4 24 V
24 V supply (AUX-PWR)
AND3 plug connector
[4]
AND3 plug connector
(male)
1 N.C.
Not assigned (reserved for N)
2 L2
L2 line connection
3 N.C.
Not assigned
4 N.C.
Not assigned
5 N.C.
Not assigned
6 L3
L3 line connection
7 N.C.
Not assigned
8 L1
L1 supply system connection
PE
PE
21328994/EN – 11/2014