6
Startup of MOVIMOT
®
with MLK30A in Easy mode
Supplementary notes for installation close to the motor
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
54
6.6.3
DIP switch
When the MOVIMOT
®
inverter is installed close to the motor, the DIP switch S1/5
must be changed from the factory setting to "ON":
S1
1
2
3
4
5
6
7
8
Meaning
Binary coding
RS485 unit address
Motor
protection
Motor
performance
level
PWM
frequency
No load
damping
2
0
2
1
2
2
2
3
ON
1
1
1
1
Off
Motor one stage
smaller
Variable
(16, 8, 4 kHz)
On
OFF
0
0
0
0
On
Adjusted
4 kHz
Off
6.6.4
Braking resistor
• For
motors without brake
, a braking resistor must be connected to the
MOVIMOT
®
.
BW1/BW2
X1
:
1
3
X1
:
1
4
X1
:
1
5
• For
brakemotors without BEM option
, no braking resistor may be connected to
the MOVIMOT
®
.
• For
brakemotors with BEM option
and external braking resistor, the external
braking resistor and the brake must be connected as follows:
BW
X1: 13
X1: 14
X1: 15
X10:1
X10:2
X10:3
M
3~
BE/BR
RD
RD
BK
L1 L2
BK
WH
BU
BU
+
~
~
BEM
13
14
15
_
U
IN
U
E
9007199895472907