4
Mechanical installation
Tightening torques
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
19
4.6.5
Modular connection box
For fastening the connection box on the mounting plate, tighten screws using 3.3 Nm
(29 lb.in).
322786187
4.6.6
Tightening torques for terminals
Use the following tightening torques for terminals during installation:
[3]
[3]
[1]
[2]
1143643275
[1]
0.8 – 1.5 Nm (7 – 13 lb.in)
[2]
1.2 – 1.6 Nm (11 – 14 lb.in)
[3]
2.0 – 2.4 Nm (18 – 21 lb.in)
21328994/EN – 11/2014