5
Electrical installation
Connection of MOVIMOT® MM../AZZK (connection option D1/D2)
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
29
5.6
Connection of MOVIMOT
®
MM../AZZK (connection option D1/D2)
Connection
of
MOVIMOT®
MM../AZZK
(connection
option
D1/D2)
The following figure shows the connection in MM../AZZK design:
M
3~
L1
L2
L3
PE
K11
F11/F12/F13
X1
:
1
3
X1
:
1
4
X1
:
1
5
X1
:
L
1
X1
:
L
2
X1
:
L
3
R
D
W
H
BE/BR
MM../AZZK
BU
X1
0
:1
X1
0
:2
X1
0
:3
BW [4]
[5]
4
2
1
3
4
2
1
3
3
1
4
2
AS-Int
AS-Interface -
24 V
V024
3
1
4
2
DI3
[3]
[1]
YE
BK
V0
4
2
1
3
V024
3
1
4
2
DI2
[2]
BK
V0
X01
X03
X02
X03 X02
X01
[6][7]
2
4
V
X5
:
2
a
,2
b
X5
:
1
a
,1
b
18014400263900683
AZZK plug connector
[1]
X03:
M12 plug connector
(female, black)
1 V024
24 V voltage supply for sensors
2 N.C.
Not assigned
3 V0
⍊
0 V reference potential for sensors
4 DI3
Sensor input DI3
5 PE
PE
[2]
X01:
M12 plug connector
(socket, black)
1 V024
24 V voltage supply for sensors
2 N.C.
Not assigned
3 V0
⍊
0 V reference potential for sensors
4 DI2
Sensor input DI2
5 PE
PE
[3]
X02:
M12 plug connector
(male, yellow)
1 AS-Int
AS-Interface data cable +
2 0 V
Reference potential AUX-PWR
3 AS-Interface -
AS-Interface data cable -
4 24 V
24 V supply (AUX-PWR)
[4]
BW.. braking resistor (only in MOVIMOT
®
without mechanical brake)
[5]
Plug connector for connecting the BEM option
[6]
24 V supply (AUX-PWR)
[7]
Reference potential AUX-PWR
21328994/EN – 11/2014