6
Startup of MOVIMOT
®
with MLK30A in Easy mode
Description of the control elements
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
36
6.2
Description of the control elements
6.2.1
Setpoint potentiometer f1
NOTICE
Loss of warranted degree of protection if the screw plugs of the f1 setpoint potenti-
ometer or the X50 diagnostic interface are installed incorrectly or not at all.
Damage to the MOVIMOT
®
inverter.
• After setting the setpoint, make sure the screw plug of the setpoint potentiometer
has a seal and screw it in.
Use the f1 potentiometer to adjust setpoint f1.
100
[1]
2
1
0
2 3 4 5 6 7 8 9 10
75
25
50
6
5
f1
f1 [Hz]
18014398838894987
[1]
Potentiometer setting
Setpoint f1 is active when the AS-Interface bit DO2 "speed f2/sped f1" = "0".
6.2.2
Switch f2
Use the f2 switch to adjust setpoint f2.
Switch f2
Detent position
0
1
2
3
4
5
6
7
8
9
10
Setpoint f2 [Hz]
5
7
10
15
20
25
35
50
60
70 100
Minimum frequency
[Hz]
2
5
7
10
12
15
20
25
30
35
40
Setpoint f2 is active when the AS-Interface bit DO2 "speed f2/speed f1" = "1".
6.2.3
Switch t1
Use switch t1 to set the acceleration of the MOVIMOT
®
drive. The ramp time is based
on a setpoint step change of 1500 rpm (50 Hz).
Switch t1
Detent position
0
1
2
3
4
5
6
7
8
9
10
Ramp time t1 [s]
0.1 0.2 0.3 0.5 0.7
1
2
3
5
7
10
3
4
5
6
7
8
3
4
5
6
7
8
21328994/EN – 11/2014