7
Service
Unit replacement
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
64
• Switch t1
on the new MOVIMOT
®
inverter analogously to the control elements of the previous
MOVIMOT
®
inverter.
4. Unlock the drive ID module of the new MOVIMOT
®
inverter and pull it out carefully.
1.
2.
1.
18014399028685579
5. Unlock the drive ID module of the previous MOVIMOT
®
inverter as well and pull it
out carefully.
Insert this drive ID module into the new MOVIMOT
®
inverter.
Make sure that the drive ID module locks in place.
6. Place the new MOVIMOT
®
inverter onto the connection box and screw it on.
7. Supply voltage to the MOVIMOT
®
inverter.
INFORMATION
When switching on the new inverter the first time after a unit replacement, the 24 V
supply must be connected for at least 10 seconds without interruptions.
After the unit replacement, it can take up to 6 s before the MOVIMOT
®
inverter sig-
nals the ready signal.
8. Check whether the new MOVIMOT
®
inverter is functioning properly.
21328994/EN – 11/2014