6
Startup of MOVIMOT
®
with MLK30A in Easy mode
Startup procedure
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
51
6.5.5
Setpoint scaling via parameter bits
The following table lists the parameter bits for setpoint scaling
The setpoint scaling does only affect setpoint f1 that can be set externally.
Setpoint f2 and the minimum frequency are not affected by the scaling.
The following table lists the possible setpoint frequencies for setpoint potentiometer
f1 = 100 Hz (3000 rpm) and f1 = 50 Hz (1500 rpm):
Parameter bits
Factor
Setpoint frequency [Hz]
P3 P2 P1 P0
for f1 = 100 Hz
f1 = 50 Hz
1
1
1
1
1.00
100
50
1
1
1
0
1.11
90
45
1
1
0
1
1.25
80
40
1
1
0
0
1.43
70
35
1
0
1
1
1.67
60
30
1
0
1
0
2.00
50
25
1
0
0
1
2.22
45
22.5
1
0
0
0
2.50
40
20
0
1
1
1
2.86
35
17.5
0
1
1
0
3.33
30
15
0
1
0
1
4.00
25
12.5
0
1
0
0
5.00
20
10
0
0
1
1
6.67
15
7.5
0
0
1
0
10.00
10
5
0
0
0
1
14.30
7
3.5
0
0
0
0
20.00
5
2.5
21328994/EN – 11/2014