6
Startup of MOVIMOT
®
with MLK30A in Easy mode
Startup procedure
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
47
INFORMATION
The first speed is infinitely variable during operation using the setpoint potentiometer
f
1
which is accessible from outside.
Speeds f1 and f2 can be set independently of each other.
9. Set the ramp time at the switch t1.
The ramp time refers to a setpoint step change of 1500 rpm (50 Hz).
Switch t1
Detent position
0
1
2
3
4
5
6
7
8
9
10
Ramp time t1 [s]
0.1 0.2 0.3 0.5 0.7
1
2
3
5
7
10
10.Place the MOVIMOT
®
inverter onto the connection box and screw it on tightly.
11.Switch on the following voltages.
• AS-Interface voltage
• DC 24 V auxiliary voltage
(only for 24 V supply via the black AUX-PWR cable)
• Mains voltage
6.5.1
Assigning the slave address
MOVIMOT
®
drives with MLK3.A AS-Interface option are set to address 0 by default.
You have the following options for assigning the AS-Interface address of the
MOVIMOT
®
drive with AS-Interface option MLK3.A (address 1 - 31):
• Addresses are assigned automatically within a configured AS-Interface system
when replacing a MOVIMOT
®
drive with MLK3.A AS-Interface option.
The following prerequisites must be fulfilled:
– The new MOVIMOT
®
drive with AS-Interface option MLK3.A must have the ad-
dress 0.
– If you need to replace several MOVIMOT
®
drives with AS-Interface option
MLK3.A, you must replace them individually (one after the other).
• Manual address assignment via the system master
The drives must be connected to the AS-Interface cable one after another. Doing
so prevents several MOVIMOT
®
drives with AS-Interface option MLK3.A from being
assigned the same address.
• Manual address assignment using a hand-held AS-Interface programming device.
Observe the notes in the next chapter when connecting the MOVIMOT
®
drive with
AS-Interface option MLK3.A to the AS-Interface cable.
3
4
5
6
7
8
21328994/EN – 11/2014