4
Mechanical installation
Mounting MOVIMOT® inverter close to the motor
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
17
4.4.3
Installation in damp locations or in the open
Observe the following notes for mounting the MOVIMOT
®
drive in damp areas or in
the open:
• Use suitable cable glands for the incoming cables. Use reducing adapters if neces-
sary.
• Coat the threads of the cable glands and screw plugs with sealing compound and
tighten them properly. Then coat the cable glands again.
• Seal the cable entry properly.
• Thoroughly clean the sealing surfaces of the MOVIMOT
®
inverter before re-assem-
bly.
• If the corrosion protection coating is damaged, restore the coating.
• Check whether the degree of protection specified on the nameplate is permitted in
the ambient conditions on site.
4.5
Mounting MOVIMOT
®
inverter close to the motor
Mounting
MOVIMOT®
inverter
close to the
motor
The following figure shows the mounting dimensions for mounting the MOVIMOT
®
in-
verter close to the motor:
A
B
M6
M6
9007199713018763
Size
Type
A
B
1
MM03D503-00 – MM15D-503-00
MM03D233-00 – MM07D-233-00
140 mm
65 mm
2/2L
MM22D503-00 – MM40D-503-00
MM11D233-00 – MM22D-233-00
170 mm
65 mm
21328994/EN – 11/2014