6
Startup of MOVIMOT
®
with MLK30A in Easy mode
Startup procedure
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
52
6.5.6
Inverter behavior depending on the AS-Interface bits
The following table shows the behavior of the MOVIMOT
®
inverter depending on the
status of the AS-Interface bit:
Inverter
behavior
AS-Interface bit
Status
LED
Supply
system
X1: L1-L3
DO3
DO2
DO0
DO1
Reset/
control-
ler ena-
ble
Speed f2/
speed f1
CW op-
eration/
stop
CCW
opera-
tion/
stop
Inverter off
0
0
x
x
x
Flashing
yellow
Inverter off
1
0
x
x
x
Yellow
Stop, no supply
system
0
1
x
x
x
Flashing
yellow
Stop
1
1
x
0
0
Yellow
CW rotation with
f1
1
1
0
1
0
Green
CCW rotation
with f1
1
1
0
0
1
Green
CW rotation with
f2
1
1
1
1
0
Green
CCW rotation
with f2
1
1
1
0
1
Green
Stop
1
1
x
1
1
Yellow
0 = No voltage
1 = Voltage
x = Any