Startup
13.Check the functions of the MOVIGEAR
®
drive unit.
Optimize the parameters, if required.
14.Disconnect the PC from the MOVIGEAR
®
inverter.
15.Make sure the screw plug of the diagnostics interface has a seal and screw it in.
16.Switch on the following voltages.
• AS-Interface voltage
• Supply voltage
17.Set the desired AS-Interface address.
• With a hand-held programming device
• With an AS-Interface master (see description master)
6.5.2
Assigning the slave address
MOVIGEAR
®
drives with AS-Interface are assigned address 0 at the factory.
You have the following options for assigning the AS-Interface address of the
MOVIGEAR
®
inverter with AS-Interface (address 1 - 31):
• Addresses are assigned automatically within a configured AS-Interface system when
replacing a MOVIGEAR
®
drive with AS-Interface.
The following prerequisites must be fulfilled:
– The new MOVIGEAR
®
drive with AS-Interface must have the address 0.
– If you need to replace several MOVIGEAR
®
drives with AS-Interface , you must
replace them individually (one after the other).
• Manual address assignment via the plant master
The drives must be connected to the AS-Interface cable one after another. Doing so
prevents several MOVIGEAR
®
drives with AS-Interface from having assigned the
same address.
• Manual address assignment using a hand-held AS-Interface programming device.
Observe the notes in chapter "Assigning the slave address using a hand-held
programming device" when connecting the MOVIGEAR
®
drive with AS-Interface to
the AS-Interface cable.
NOTICE
The enclosure specified under technical data only applies if the screw plugs of the
setpoint potentiometer and the diagnostic interface are installed correctly.
Missing or incorrectly installed screw plugs can cause damage to the MOVIGEAR
®
inverter.