Operating Instructions – MOVIGEAR® DAC-B
131
8
Description of power section parameters
Parameters
Enable hours
index 8329.0
The parameter indicates the total number of hours for which the power section was in
ENABLE operating state:
• Storage cycle every 15 min
• Unit: [h]
Work index 8330.0
The parameter indicates the total of active electrical energy the motor has consumed:
• Storage cycle every 15 min
• Unit: [kWh]
Power section parameters \ display values \ binary outputs
Binary output
DO01
index 8340.0 –
8347.0
The parameter indicates the present state of binary output DO01 on the application
option (e.g. signal relay K1) and the current function assignment.
Power section parameters \ display values \ unit data
Unit series index
9701.10
The parameter indicates the unit series, for example "MOVIGEAR
®
".
Variant ID index
9701.11
The parameter indicates the unit generation, for example "B".
Unit name
index 9701.1,
9701.2, 9701.3,
9701.4, 9701.5
The parameter indicates the type designation of the power section.
Unit variant index
10204.2
The parameter indicates the MOVIGEAR
®
installation technology, e.g.:
• DBC = Direct Binary Communication
• DAC = Direct AS-Interface Communication
• DSC = Direct SBus Communication
• SNI = Single Line Network Installation
Device signature
index 9823.1,
9823.2, 9823.3,
9823.4, 9823.5
The parameter is used to indicate and enter the device signature. This parameter is
used to assign a name to the power section so you can identify it in the hardware tree
or in other visualization elements.
Rated unit current
(rms) index 8361.0
The parameter indicates the rated unit current (rms value).
• Unit: [mA]
Rated motor
torque
index 9610.1
The parameter indicates the available continuous torque of the motor.
• Unit: [Nm]
Basic unit firmware
index 9701.30
The parameter indicates the part number of the firmware used in the power section.
0