Operating Instructions – MOVIGEAR® DAC-B
203
12
Inspection and maintenance work on the MOVIGEAR
®
drive
Inspection and Maintenance
Filling in the oil
1. Observe the notes in chapter "Preliminary work for inspection and maintenance on
MOVIGEAR
®
".
2. SEW-EURODRIVE recommends that you fill in the new oil in the position depicted in
the figure below.
3. Fill in new oil of the same type via the lower bore hole [1].
It is easier to fill in the oil when you also remove the upper breather plug [2] or
breather valve.
For the required oil quantity, refer to the nameplate or the chapter "Technical data
and dimension sheets/Lubricant fill quantities" depending on the mounting position.
4. Re-insert the screw plug and the breather valve. Depending on the mounting position
used, observe the mounting position sheet.
5. Touch up or renew the surface protection/anticorrosion coating.
Recommended
position
The following figure shows the position recommended for filling the new oil.
NOTICE
Filling in the wrong oil may result in significantly different lubricant characteristics.
Potential damage to property
• Do not mix different synthetic lubricants and do not mix synthetic with mineral
lubricants.
• Synthetic oil is used as the standard lubricant.
2360459915
[1]
[2]