![SEW-Eurodrive MOVIGEAR DAC B Operating Instructions Manual Download Page 67](http://html1.mh-extra.com/html/sew-eurodrive/movigear-dac-b/movigear-dac-b_operating-instructions-manual_1250343067.webp)
Operating Instructions – MOVIGEAR® DAC-B
67
5
Plug connectors
Electrical Installation
5.6.3
Plug connector positions
The following figure shows the possible plug connector positions. A difference is made
between plug connectors with selectable position and plug connectors with fixed
position:
Plug connector
Color
Position Location
X5132: Digital inputs/outputs
–
Can be
selected
X, 2 or 3,
not together with X1203_1, X1203_2
X5502: STO – IN
Orange
Fixed
3 (left)
X5503: STO – OUT
Orange
Fixed
3 (right)
X4271: AS-Interface communication
interface
Yellow
Fixed
X
X5011: AS-Interface sensors
Black
Fixed
2
X1203_1: AC 400 V connection
1)
1) The plug connector X1203_1 is also available separately (i.e. without plug connector X1203_2).
Black
Can be
selected
X, 2 or 3, not together with X5132
X1203_2: AC 400 V connection
Black
Can be
selected
X, 2 or 3, not together with X5132
[1] Pressure compensation
2)
2) Only in connection with the optional package for wet areas, see chapter "Unit design" as well.
–
Fixed
Depends on mounting position
2446060811
X5132
X5132
X5132
X1203_1
X1203_1
X1203_1
X1203_2
X1203_2
X1203_2
[1]
X5502
X5503
X4271
X5011
[1]
X
2
3
Summary of Contents for MOVIGEAR DAC B
Page 2: ...SEW EURODRIVE Driving the world...
Page 257: ......