8
Description of power section parameters
Parameters
Error source t-0 –
4 index 10404.6,
10404.7, 10404.8,
10404.9, 10404.10
The parameter indicates the error source:
• 0 = No error
• 1 = Power section
• 2 = Command pcb
Actual speed t-0 –
4 index 8401.0,
8402.0, 8403.0,
8404.0, 8405.0
The parameter indicates the actual motor speed at the time of the error.
• Unit [rpm]
Apparent output
current t-0 – 4
index 8406.0,
8407.0, 8408.0,
8409.0, 8410.0
The parameter indicates the apparent output current in percent of the rated unit current
at the time of the error.
• Unit [%]
Active output cur-
rent t-0 – 4
index 8411.0,
8412.0, 8413.0,
8414.0, 8415.0
The parameter indicates the active output current in percent of the rated unit current at
the time of the error.
• Unit [%]
Unit utilization t-0 –
4 Index 8414.0,
8417.0, 8418.0,
8419.0, 8420.0
The parameter indicates the unit utilization Ixt at the time of the error.
• Unit: [%]
Motor utilization
t-0 – 4
index 8441.0,
8442.0, 8443.0,
8444.0, 8445.0
The parameter indicates the motor utilization calculated using motor model and current
at the time of the error.
• Unit: [%]
DC link voltage t-
0 – 4 index 8421.0,
8422.0, 8423.0,
8424.0, 8425.0
The parameter indicates the voltage measured in the DC link circuit at the time of the
error.
• Unit: [V]