Description of power section parameters
Parameters
Power section
status t-0 – 4
index 8391.0,
8392.0, 8393.0,
8394.0, 8395.0
The parameter indicates the operating state of the power section at the time of the error:
• 0 = Inhibited
• 1 = Controller inhibit
• 2 = System error
• 3 = No enable
• 6 = Enabled
• 7 = Rapid stop
• 8 = Integrator stop
• 9 = Emergency stop
• 12 = Pos. mode
• 15 = Reference travel
Operating hours
t-0 – 4
index 8426.0,
8427.0, 8428.0,
8429.0, 8430.0
The parameter indicates the total number of hours for which the inverter has been
connected to the mains at the time of the error.
• Storage cycle every 15 min
• Unit: [h]
Enable hours t-0 –
4 index 8431.0,
8432.0, 8433.0,
8434.0, 8435.0
The parameter indicates the total number of hours for which the power section was in
ENABLE operating state at the time of the error.
• Storage cycle every 15 min
• Unit: [h]
Work t-0 – 4
index 10083.1,
10083.2, 10083.3,
10083.4, 10083.5
The parameter indicates the total of active electrical energy the motor has consumed at
the time of the error.
• Storage cycle every 15 min
Heat sink
temperature t-0 – 4
index 8396.0,
8397.0, 8398.0,
8399.0, 8400.0
The parameter indicates the heat sink temperature of the power section at the time of
the error.
• Unit: [°C]
Motor temperature
t-0 – 4
index 10070.1,
10070.2, 10070.3,
10070.4, 10070.5
The parameter indicates the motor temperature measured at the time of the error.
• Unit: [°C]