![SEW-Eurodrive MOVIGEAR DAC B Operating Instructions Manual Download Page 82](http://html1.mh-extra.com/html/sew-eurodrive/movigear-dac-b/movigear-dac-b_operating-instructions-manual_1250343082.webp)
82
Operating Instructions – MOVIGEAR® DAC-B
6
Description of the DIP switches
Startup
6.3
Description of the DIP switches
6.3.1
Overview
The following figure shows the DIP switches S1 and S2:
The following table shows the functions of DIP switch S1:
The following table shows the functions of DIP switch S2:
2391265547
DIP switch
S1
1
2
3
4
PWM cycle
frequency
Deactivate
DynaStop
without enable
Reserved
Reserved
ON
8 kHz
On
Reserved
Reserved
OFF
4 kHz
Off
Reserved
Reserved
DIP switch
S2
1
2
3
4
Startup mode
Reserved
Direction of
rotation
reversal
Speed
monitoring
1)
1) The DIP switch is only active in "Easy" mode
ON
Expert
Reserved
On
On
OFF
Easy
Reserved
Off
Off
34567
34567
ON
ADE04SA
1
2
3
4
ON
ADE04SA
1
2
3
4
t1
S1
S2
f2 f1
1 2 3 4
1 2 3 4
ON
DIP
1 2 3 4
ON
DIP
1 2 3 4
S2
S1
NOTICE
Set the DIP switches using suitable tools, e.g. a flat tip screwdriver with a blade width
≤
3 mm.
The force used for setting the DIP switches must not exceed 5 N.