6
Electrical installation
PC connection
Manual – EtherCAT
®
Interfaces, Field Distributors
64
6.11
PC connection
Underneath the screw plug, the fieldbus interfaces have an RJ10 diagnostic interface
for startup, parameterization, and service. The diagnostic interface is connected to a
commercially available PC/Laptop via the interface adapter with USB port.
MF../MQ..
RJ10
USB
Interface adapter
28082465675
The following interface adapters are available:
Designation
Part number
USB11A
08248311
USM21A
28231449
The following components are included each in the scope of delivery:
•
Interface adapter
•
Cable with RJ10 plug connector
•
USB interface cable
Establish a connection
Proceed as follows to establish the connection:
ü
Wait for the MOVIMOT
®
drive to cool down sufficiently before touching it.
1. Remove the screw plugs of the diagnostic interface.
2. Connect the fieldbus interface and the interface adapter with the RJ10 plug con-
nector using a cable.
3. Connect the PC/laptop to the interface adapter using the USB interface cable.
25809148/EN – 01/2019