
15
Technical data
Technical data for field distributors
Manual – EtherCAT
®
Interfaces, Field Distributors
122
15.4
Technical data for field distributors
15.4.1
MF../Z.3. field distributors
MF../Z.3.
Supply voltages
V
line
AC 3 x 380 V -10% – AC 500 V +10%
AC 3 x 200 V -10% – AC 240 V +10%
Line frequency
f
line
50 – 60 Hz
Max. permitted total cur-
rent X1
(X1 terminal)
I
max
32 A (according to UL max. 30 A)
Max. permitted total current
X21
(X21 terminals)
32 A
Max. permitted total cur-
rent X20
(X20 terminals)
12 A
Ambient temperature
-25 °C – 60 °C
Storage temperature
-25 °C – 85 °C
Degree of protection
IP65 (fieldbus interface and motor connection cable attached and
fastened, all plug connections sealed)
Interface
PROFIBUS, PROFINET IO, EtherNet/IP™, EtherCAT
®
, DeviceNet™
Permitted motor cable
length
max. 30 m (with SEW‑EURODRIVE hybrid cable, type B)
for cross section reduction compared to the supply system cable
Note the line fusing.
Mass
Approx. 1.3 kg
25809148/EN – 01/2019