15
Technical data
Technical data for field distributors
Manual – EtherCAT
®
Interfaces, Field Distributors
126
15.4.5
MF../MM../Z.8. field distributors with operating point 230 V/60 Hz
MF../MM..-233-00/Z.8.
MOVIMOT
®
inverter
MM
03D
MM
05D
MM
07D
MM
11D
MM
15D
MM
22D
Size
1
2
Connection voltages
V
line
AC 3 x 200 V -10% – AC 240 V +10%
Line frequency
f
line
50 – 60 Hz
Max. permitted total cur-
rent X1
(X1 terminal)
I
max
32 A (according to UL max. 30 A)
Motor power S1
P
Mot
0.37 kW
0.5 HP
0.55 kW
0.75 HP
0.75 kW
1.0 HP
1.1 kW
1.5 HP
1.5 kW
2.0 HP
2.2 kW
3.0 HP
Nominal line current
I
line
AC 1.9 A
AC 2.4 A
AC 3.5 A
AC 5.0 A
AC 6.7 A
AC 7.3 A
Nominal output current
I
N
AC 2.5 A
AC 3.2 A
AC 4.0 A
AC 5.5 A
AC 7.3 A
AC 8.7 A
Output voltage
V
O
0 – V
line
Max. permitted total cur-
rent X21
(X21 terminals)
32 A
Max. permitted total cur-
rent X20
(X20 terminals)
12 A
Maintenance switch
Load disconnector
Type: ABB OT16ET3HS3ST1
Switching: black/red, triple lock
Ambient temperature
-25 °C – 40 ˚C (P
N
reduction: 3% I
N
per K to max. 55 °C)
Storage temperature
-25 °C – 85 °C
Degree of protection
IP65 (fieldbus interface, power supply connection cover, MOVIMOT
®
in-
verter and motor connection cable attached and fastened, all plug con-
nections sealed)
Interface
PROFIBUS, PROFINET IO, EtherNet/IP™, EtherCAT
®
, DeviceNet™
Permitted motor cable
length
15 m (with SEW‑EURODRIVE hybrid cable, type A)
Mass
Approx. 5.2 kg
Approx. 6.7 kg
25809148/EN – 01/2019