6
Electrical installation
Hybrid cable connection
Manual – EtherCAT
®
Interfaces, Field Distributors
63
6.10.2
Hybrid cable between MFZ.7. or MFZ.8. field distributor and AC motors
The following figure shows the hybrid cable for connecting the AC motor
part number
01867423
.
MFZ.7
+
MFZ.8
9007200402006667
The following table shows the terminal assignment of the hybrid cable in the motor ter-
minal box:
Terminal assignment
Motor terminal
Wire color/hybrid cable designation
U1
Black/U1
V1
Black/V1
W1
Black/W1
4a
Red/13
3a
White/14
5a
Blue/15
1a
Black/1
2a
Black/2
PE terminal
Green/ shield end (inner shield)
INFORMATION
Attach the outer shield of the cable to the housing of the motor terminal box using an
EMC metal cable gland.
25809148/EN – 01/2019