4
Device structure
Type designation EtherCAT® interfaces
Manual – EtherCAT
®
Interfaces, Field Distributors
15
4.1.2
Device structure of MFZ connection module
The following figure shows the MFZ connection module.
[3]
[5]
[4]
[3]
[4]
[2]
[3]
[1]
9007200390917003
[1] Terminal strip X20
[2] Isolated terminal block for 24 V through-wiring
(NOTICE: Do not use for shielding.)
[3] M20 cable gland
[4] M12 cable gland
[5] Grounding terminal
The scope of delivery includes 2 EMC cable glands.
4.2
Type designation EtherCAT
®
interfaces
Type
designation
EtherCAT®
interfaces
4.2.1
Nameplate
Order-specific
nameplate
The following figure shows an example of the order-specific nameplate of the MFE../
MM../Z.8 field distributors:
P-Motor = 1,5kW
95.7416041003.0001.17
S0#:
0/ AGB1
IP65 ML 0001
MFE52B/MM15D-503-00/Z28F
Type:
U= 3x380...500V I= 3,5A AC
Input:
Made in Germany
Feldverteiler
Field Distributor
01
UL
®
LISTED
IND.CONT.EC
2D06
C
US
General name-
plate
The following figure shows an example of the general nameplate of the MFE../MM../
Z.8 field distributors:
Input:
Input:
Output to next Field Distributor:
Output to drive:
3x200...500V
U=
30A AC
Imax=
Imax=
3x200...500V
50...60Hz
U=
f=
1,3...3,5A AC
Imax=
3x200...500V
U=
30A AC
3x0...Uinput
0,37...1,5kW
U=
P-Motor=
1,6...4,0A AC
Imax=
25809148/EN – 01/2019