3
Safety notes
Functional safety technology
Manual – EtherCAT
®
Interfaces, Field Distributors
11
3.5
Functional safety technology
The product must not perform any safety functions without a higher-level safety sys-
tem, unless explicitly allowed by the documentation.
3.6
Transport
Inspect the shipment for damage as soon as you receive the delivery. Inform the ship-
ping company immediately about any damage. If the product is damaged, it must not
be assembled, installed or started up.
Observe the following notes when transporting the device:
•
Ensure that the product is not subject to mechanical impact.
•
Before transportation, cover the connections with the supplied protection caps.
•
Only place the product on the cooling fins or on the side without connectors during
transportation.
•
Always use lifting eyes if available.
If necessary, use suitable, sufficiently dimensioned handling equipment.
Observe the information on climatic conditions in the chapter "Technical data" of the
documentation.
3.7
Installation/assembly
Ensure that the product is installed and cooled according to the regulations in the doc-
umentation.
Protect the product from strong mechanical strain. The product and its mounting parts
must never protrude into the path of persons or vehicles. Ensure that components are
not deformed and insulation spaces are not changed, particularly during transportation
and handling. Electric components must not be mechanically damaged or destroyed.
Observe the notes in chapter
) in the documenta-
tion.
3.7.1
Restrictions of use
The following applications are prohibited unless the device is explicitly designed for
such use:
•
Use in potentially explosive atmospheres
•
Use in areas exposed to harmful oils, acids, gases, vapors, dust, and radiation
•
Operation in applications with impermissibly high mechanical vibration and shock
loads in excess of the regulations stipulated in EN 61800-5-1
•
Use at an elevation of more than 4000 m above sea level
The product can be used at altitudes above 1000 m above sea level up to 4000 m
above sea level under the following conditions:
•
The reduction of the nominal output current and/or the line voltage is considered
according to the data in chapter "Technical data" (→
25809148/EN – 01/2019