4
Device structure
Type designation EtherCAT® interfaces
Manual – EtherCAT
®
Interfaces, Field Distributors
16
The MF../Z.1 fieldbus interface does not have a general nameplate.
01
Only field distributors marked with the FS logo for functional safety may be installed in
safety applications. For field distributors marked with the FS logo, the safety function
must be described in the documentation.
4.2.2
Type designation
MFE
Fieldbus interface
MFP..
= PROFIBUS
MQP..
= PROFIBUS with integrated minicontroller
MFE..
= PROFINET IO, EtherNet/IP™ or EtherCAT
®
MFD..
= DeviceNet™
MQD..
= DeviceNet™ with integrated minicontroller
72
Connections
21 = 4 × I, 2 x O
(connection via terminals)
22 = 4 × I, 2 x O
(connection via plug con terminals)
32 = 6 × I
(connection via plug con terminals)
52 = 4 × I, 2 × I/O
(connection via plug con terminals) for
PROFINET IO
62 = 4 × I, 2 × I/O
(connection via plug con terminals) for
EtherNet/IP™
72 = 4 × I, 2 × I/O
(connection via plug con terminals) for
EtherCAT
®
A
Design
/
Z21
Connection module
Z21
= for PROFIBUS, PROFINET IO, EtherNet/IP™
and EtherCAT
®
Z31
= for DeviceNet™
D
Design