Rev.1.2 – 7.2018.EL950.1.3.1086C
59
d. Inspect and remove jammed bill.
e. Replace lower unit to resume normal operation.
REFRIGERATION DECK
Your Drink unit incorporates a high efficiency refrigeration system having two air circulation fans to chill the
cans and bottles. The refrigeration unit can be easily accessed by opening the Drink unit door and sliding
the front grill up and out. Remove the single screw from the center floor of the refrigeration deck and unplug
the wire harnesses on the side of the deck (Fig. 23). The refrigeration deck can now be pulled out from the
vendor. Please make sure you unplug wire harnesses prior to pulling all the way out. Do not tip the
refrigeration deck more than 20° in any direction.
Figure 23 – Refrigeration deck
The refrigeration deck is a modular system consisting of Compressor, Condenser, Condenser fan,
Evaporator, Evaporator Fan, Accumulator or Dryer, and Temperature Sensor which communicates to the
VMC. The temperature is pre-set at the factory for efficient and effective operation.
Condenser
Gently
clean fins
on a regular
basis
Compressor
Wire Harnesses – Unplug 3 harnesses here and
feed through dividing wall before removal of the
deck
Remove single
screw