Rev.1.2 – 7.2018.EL950.1.3.1086C
33
MOTOR TYPE
Note: Must be set to 3 Wire.
STEP
DISPLAY
1.
Press Service Mode Button
Motor Count or Error Code **
2.
Press 4 for Configuration
Configuration
3.
Press 0 for Advanced Config
Password:
Use keypad to enter password
4.
Press 3 for Motor Type menu
Motor Type (Current Setting)
*-Exit, no change 3-Edit
5.
Press 3 to toggle 3-Wire or 2-Wire
Motor Type (Choice Flashing)
*-Exit, no change # to Save
6.
Press # to save the setting
Motor Type (New Setting)
*-Exit, no change 3-Edit
7.
Press * three times to exit
0.00
TEMP
Note: Must be set to COLD.
STEP
DISPLAY
1.
Press Service Mode Button
Motor Count or Error Code **
2.
Press 4 for Configuration
Configuration
3.
Press 0 for Advanced Config
Password:
Use keypad to enter password
4.
Press 4 for Temp menu
Temp (Current Setting)
*-Exit, no change 4-Edit
5.
Press 4 to toggle Snack, Cold, Cold Food, Slackened,
Eng Test, Dual Zone, Dual Upper -6, Chilled, MZF,
MZF -2, MZF -5, SZ Frozen, SZ Frozen -2,
SZ Frozen -5, SZ Cold, SZ Cold -1
Temp (Choice Flashing)
*-Exit, no change # to Save
6.
Press # to save the setting
Temp (New Setting)
*-Exit, no change 4-Edit
7.
Press * three times to exit
0.00
SEL STYLE
Note: Must be set to 3 Digit.
STEP
DISPLAY
1.
Press Service Mode Button
Motor Count or Error Code **
2.
Press 4 for Configuration
Configuration
3.
Press 0 for Advanced Config
Password:
Use keypad to enter password
4.
Press 5 for Sel Style
Sel Style (Current Setting)
*-Exit, no change 5-Edit
5.
Press 5 to toggle 3 digit, 2 Dgt 40+, 2-Dgt ever, */# USD Sel Style (Choice Flashing)
*-Exit, no change # to Save
6.
Press # to save the setting
Sel Style (New Setting)
*-Exit, no change 5-Edit
7.
Press * three times to exit
0.00