User Manual SM6026
57
OFF, OPEN SINGLE, SHORT SINGLE and LOAD.
l) Press ON to turn on the point-frequency correction function of
FREQ 1
.
m) Press [1][0][0], +100 will be displayed in the prompt information zone and the soft key zone will display
the following available units: Hz, kHz and MHz. Press kHz, the
FREQ 1
zone will be changed as
100.000kHz (the same with the test frequency).
n) Move the cursor to the
REF A
: zone of the frequency 1. Press [1][1], +11 will be displayed in the
prompt information zone and the following available units will be displayed in the soft key zone: p, n, μ,
m and k. Press n, this zone will be changed as 11.0000nF.
o) Move the cursor the
REF B
: zone of the frequency 1. Press [0][.][0][0][0][5], +0.0005 will be displayed
in the prompt information zone and the following available units will be displayed in the soft key zone: p,
n, μ, m and k. Press [ENTER], this zone will be changed as 0.00050.
p) Move the cursor to Freq 1. The following soft keys will be displayed: ON, OFF, OPEN SINGLE,
SHORT SINGLE and LOAD.
q) Hold the test fixture be in open status and keep user’s hands or other interference source be far away
from the test fixture. Press the soft key Open to execute open correction.
r) Insert the shorting plate into the test fixture. Please ensure that the short plate and the reeds of the test
fixture have good contact.
s) Press the soft key SHORT SINGLE to execute short correction.
t) Insert a standard capacitance into the test fixture. Please ensure that the pins of the standard
capacitance have good connection with the reeds of the test fixture.
u) Press the soft key LOAD to execute load correction.
2) Note
a) Because of the different software editions, the soft keys and status information may be different form
this book, but it may not affect users’ understanding.
b) The load correction is only valid for the components with the same specification. If the specification is
changed, it is required to redo load Correction.
6
Performance and Test
6.1 Test function
6.1.1 Parameter and symbol
C
:
capacitance
L
:
Inductance
R
:
resistance
Z
:
impedance
Y
:
Admittance
X
:
reactance
B
:
susceptance
G
:
Conductance
D
:
dissipation
:
phase angle
Q
:
Quality factor
Lk: leakage inductance
DCR: DC resistance
Test combination
Parameters described above are combined in the following modes:
Primary parameter
Z
,
Y
L
,
C
R
G
Secondary parameter
(
deg phase
),
(
rad radian
)
D
,
Q
,
R
S
,
R
P
,
G
X
B
There is no combination for DCR.
Mathematical operation